ID:22508 Blocks <block_name> and <block_name> are placed at paired locations <location> and <location> but do not have matching parameter settings

CAUSE: The placer cannot pair the specified blocks at the given locations because some of the parameter settings, such as transceiver width or gear box ratio, do not match.

ACTION: Place the block(s) at different location(s) or modify the design.